RKC INSTRUMENT INC.
All Rights Reserved, Copyright 2004, RKC INSTRUMENT INC.
Digital Controller
REX-C100/C400/C410/C700/C900
INSTRUCTION MANUAL
IMNZC21-E1
Thank you for purchasing the RKC instrument. In order to achieve maximum performance
and ensure proper operation of your new instrument, carefully read all the instructions
in this manual. Please place this manual in a convenient location for easy reference.
An external protection device must be installed if failure of this
instrument could result in damage to the instrument, equipment or
injury to personnel.
All wiring must be completed before power is turned on to prevent
electric shock, fire or damage to instrument and equipment.
This instrument must be used in accordance with the specifications
to prevent fire or damage to instrument and equipment.
This instrument is not intended for use in locations subject to
flammable or explosive gases.
Do not touch high-voltage connections such as power supply
terminals, etc. to avoid electric shock.
RKC is not responsible if this instrument is repaired, modified or
disassembled by other than factory-approved personnel.
Malfunction can occur and warranty is void under these conditions.
This is a Class A instrument. In a domestic environment, this
instrument may cause radio interference, in which case the user
may be required to take adequate measures.
This instrument is protected from electric shock by reinforced
insulation. Provide reinforced insulation between the wire for the
input signal and the wires for instrument power supply, source of
power and loads.
Be sure to provide an appropriate surge control circuit respectively
for the following:
- If input/output or signal lines within the building are longer than 30
meters.
- If input/output or signal lines leave the building, regardless the
length.
This instrument is designed for installation in an enclosed
instrumentation panel. All high-voltage connections such as power
supply terminals must be enclosed in the instrumentation panel to
avoid electric shock by operating personnel.
All precautions described in this manual should be taken to avoid
damage to the instrument or equipment.
All wiring must be in accordance with local codes and regulations.
All wiring must be completed before power is turned on to prevent
electric shock, instrument failure, or incorrect action. The power
must be turned off before repairing work for input break and output
failure including replacement of sensor, contactor or SSR, and all
wiring must be completed before power is turned on again.
To prevent instrument damage of failure, protect the power line and
the input/output lines from high currents with a protection device
such as fuse, circuit breaker, etc.
Prevent metal fragments or lead wire scraps from falling inside
instrument case to avoid electric shock, fire or malfunction.
Tighten each terminal screw to the specified torque found in the
manual to avoid electric shock, fire or malfunction.
For proper operation of this instrument, provide adequate
ventilation for heat dispensation.
Do not connect wires to unused terminals as this will interfere with
proper operation of the instrument.
Turn off the power supply before cleaning the instrument.
Do not use a volatile solvent such as paint thinner to clean the
instrument. Deformation or discoloration will occur. Use a soft, dry
cloth to remove stains from the instrument.
To avoid damage to instrument display, do not rub with an abrasive
material or push front panel with a hard object.
Do not connect modular connectors to telephone line.
NOTICE
This manual assumes that the reader has a fundamental knowledge
of the principles of electricity, process control, computer technology
and communications.
The figures, diagrams and numeric values used in this manual are
only for purpose of illustration.
RKC is not responsible for any damage or injury that is caused as a
result of using this instrument, instrument failure or indirect damage.
Periodic maintenance is required for safe and proper operation of
this instrument. Some components have a limited service life, or
characteristics that change over time.
Every effort has been made to ensure accuracy of all information
contained herein. RKC makes no warranty expressed or implied,
with respect to the accuracy of the information. The information in
this manual is subject to change without prior notice.
No portion of this document may be reprinted, modified, copied,
transmitted, digitized, stored, processed or retrieved through any
mechanical, electronic, optical or other means without prior written
approval from RKC.
1. PRODUCT CHECK
(1) Control action
F: PID action with autotuning
(
Reverse action
)
D: PID action with autotuning
(
Direct action
)
W: Heat/cool PID action with autotuning
(
Water cooling
)
1
A : Heat/cool PID action with autotuning
(
Air cooling
)
1
(2) Input type
,
(3) Range code
See “9. INPUT RANGE TABLE.”
(4) First control output [OUT1] (Heat-side)
M: Relay contact 8: Current (4 to 20 mA DC)
V: Voltage pulse
G: Trigger (for triac driving)
2
(5)
Second control output [OUT2] (Cool-side)
3
No symbol: When control action is F or D. M: Relay contact
V: Voltage pulse 8: Current (4 to 20 mA DC)
(6)
Alarm 1
[
ALM1
]
,
(7) Alarm 2
[
ALM2
]
N: No alarm H: Process high alarm
A: Deviation high alarm J: Process low alarm
B: Deviation low alarm K: Process high alarm with hold action
C: Deviation high/low alarm L: Process low alarm with hold action
D: Band alarm P: Heater break alarm
(
CTL-6
)
4
E: Deviation high alarm S: Heater break alarm
(
CTL-12
)
4
with hold action R: Control loop break alarm
5
F: Deviation low alarm
with hold action
G: Deviation high/low alarm with hold action
1
C100 cannot be specified in Heat/cool PID action.
2
For the C100, when control output is trigger output for triac driving, only the
ALM1 is available.
3
For the C100, there is no second control output.
4
Heater break alarm cannot be specified in case of ALM1. Also, it isn’t possible
to specify when control output is current output.
5
As control loop break alarm, only either the ALM1 or ALM2 is selected.
Check that power supply voltage is also the same as that
specified when ordering.
2. MOUNTING
2.1 Mounting Cautions
(1) This instrument is intended to be used under the following
environmental conditions.
(
IEC61010-1
)
[OVERVOLTAGE CATEGORY II, POLLUTION DEGREE 2]
(2) Use this instrument within the following ambient temperature and
ambient humidity.
Allowable ambient temperature: 0 to 50 °C
Allowable ambient humidity: 45 to 85 % RH
(3) Avoid the following when selecting the mounting location.
Rapid changes in ambient temperature which may cause
condensation.
Corrosive or inflammable gases.
Direct vibration or shock to the mainframe.
Water, oil, chemicals, vapor or steam splashes.
Excessive dust, salt or iron particles.
Excessive induction noise, static electricity, magnetic fields or noise.
Direct air flow from an air conditioner.
Exposure to direct sunlight.
Excessive heat accumulation.
Mounting brackets (C100/C400/C410/C700/C900): 2
Instruction manual
(
IMNZC21-E1): 1
<Accessories>
CAUTION
WARNING
C100
-

(1) (2) (3) (4) (6) (7)
C400
C410
C700
C900
-

(1) (2) (3) (4) (5) (6) (7)
*
*
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - 2. MOUNTING

® RKC INSTRUMENT INC. All Rights Reserved, Copyright  2004, RKC INSTRUMENT INC. Digital Controller REX-C100/C400/C410/C700/C900 INSTRUCTION MANUAL

Seite 2 - 3. WIRING

IMNZC21-E1 2 2.2 Dimensions C100 (Unit: mm) C400 (Unit: mm) C410 (Unit: mm) C700 (Unit: mm) C900 (Unit: mm) Panel thickness: 1 to 5 mm or 5

Seite 3 - 3.2 Terminal Configuration

IMNZC21-E1 3 3.2 Terminal Configuration Power supply Control output Input NO: Normally open 6 7 8 9 10 14 12 1 2 3 4 5 AC 24V DC 100−240V AC 24V 7

Seite 4 - 5. SETTING

IMNZC21-E1 4 4. PARTS DESCRIPTION (1) C100 PV SV (2) (3) (4) (5) (6) (7) PV SV (3) C410 (1) (3) (4) (5) (6) (7) PV SV (1) (4) (5) (6) (7) C400 (2)

Seite 5

IMNZC21-E1 5 Symbol Name Setting range Description Factory set value Heater break alarm (HBA) set value 1 0.0 to 100.0 A Alarm value is set by

Seite 6 - 7. INITIAL SETTING

IMNZC21-E1 6 5.3 Changing Parameter Settings Procedures to change parameter settings are shown below. zChange the set value (SV) Change the se

Seite 7 - IMNZC21-E1

IMNZC21-E1 77.3 Initial Setting Menu Display flowcharts in Initialization mode are shown in the following. Do not change to the section paramet

Seite 8 - 9. INPUT RANGE TABLE

IMNZC21-E1 APR. 2004 ® RKC INSTRUMENT INC. HEADQUARTERS: 16-6, KUGAHARA 5-CHOME, OHTA-KU TOKYO 146-8515 JAPANPHONE: 03-3751-9799 (+81 3 3751 9799) E